TAPS Products
Since its inception, TAPS has delivered over 7,000 three-phase oil-filled transformers and phase shifters to customers throughout the world. TAPS products are now in service in many countries, including the United States, Canada, Chad, China, Indonesia, Kuwait, Russia, Ecuador, Yemen, Libya and Venezuela.
All TAPS products are manufactured in an ISO-9001 registered facility. In addition to its standardized products, TAPS designs and manufactures customized transformer products to meet the needs of customers with diverse applications and extreme environments. Refer below for TAPS product scope and capabilities.
|
|
- Step-down multi-volt transformers (More Info)
- Step down to wide range, adjustable voltage for use with fixed-speed submersible pumps
- Step down to specific three-phase voltage, such as 380, 415 or 480 Volts
|
-
Basic insulation levels (BIL)
- Primary (input) BIL up to 200 kV BIL live-front, exposed bushing, step-down transformers
- Primary (input) BIL up to 150 kV BIL for dead-front, enclosed bushing, step-down transformers
- Primary (input) BIL up to 95 kV BIL for live-front, enclosed bushing, step-down transformers
- Secondary (output) BIL up to 60 kV for multiple-tap output transformers
- Secondary (output) BIL of 30 kV for output voltages below 1,200 Volts
|
- Phase-shifting isolation transformers (More Info)
- Step down to dual, phase-shifted output for use with twelve-pulse drives
- Step down to triple, phase-shifted output for use with eighteen-pulse drives
- Step down to quadruple, phase-shifted output for use with twenty-four pulse drives
|
- Winding materials
- Copper magnet wire
- Aluminum magnet wire
- Copper sheet
- Aluminum sheet
|
-
Step-up transformers (More Info)
- Step up to wide-range, adjustable voltage for use with variable-speed submersible pumps
- Step up to wide-range, adjustable voltage for use with generator-powered submersible pumps
|
- Temperature rise
- 65° C for use in ANSI/IEEE "Usual Service Conditions"
- 55° C or 45° C for use in high ambient temperature environments
|
-
Phase-shifting autotransformers (More Info)
- Phase-shifting autotransformer with dual, phase-shifted output for use with twelve-pulse drives
- Phase-shifting autotransformer with triple, phase-shifted output for use with eighteen-pulse drives
- Phase-shifting autotransformer with quadruple, phase shifted output for use with twenty-four-pulse drives
|
- Standards
- Unless otherwise specified, TAPS transformers and phase shifters are designed and built in accordance with applicable ANSI/IEEE standards.
|
|
- Ambient conditions
- Arctic
- Desert
- Jungle
- Off-shore
- Hazardous
- Indoor
|
|